Resources

Tools & Calculators

Practical tools and calculators for planning, specification and installation.

Lighting design

Lighting Simulator

Light a room, façade or landscape, see the result in 3D and check it against design targets.

Open Calculator

DMX control

DMX DIP Switch Calculator

Set DIP switches, plan DMX addresses and check for overlapping channels.

Open Calculator

LED wiring

LED Voltage Drop Calculator

Compare copper wire sizes, check voltage drop and see how much voltage reaches your LED strip.

Open Calculator

LED circuits

LED Resistor Calculator

Choose a standard series resistor, compare current and heat loss, and check the required power rating.

Open Calculator

Pixel control

Pixel LED Address Planner

Plan pixel LED runs, outputs and universe addresses for a lighting project.

Open Calculator

Energy planning

Lighting Electricity Cost Calculator

Estimate running costs for LED strips, fixtures and measured lighting, then compare an alternative setup.

Open Calculator

DALI control

DALI Bus Capacity Planner

Plan DALI-2 bus addresses and current headroom, then export a device-by-device allocation.

Open Calculator

LED drivers

Constant-Current LED Driver Checker

Match the current. Check the full voltage range. Find how many modules fit in one series string.

Open Calculator

Indoor lighting

Indoor Lighting Calculator

Estimate indoor fixture quantity, required lumens or maintained average illuminance. Compare outputs with explicit utilization and maintenance assumptions.

Open Calculator

Emergency lighting

Emergency Lighting Battery Calculator

Estimate battery runtime or capacity for a target duration, with explicit operating assumptions.

Open Calculator

Light measurement

Illuminance & Uniformity Analyzer

Map measured lux, compare average and uniformity with your targets, and keep a measurement report.

Open Calculator

Photometric data

IES / LDT Photometric Viewer

Inspect IES and LDT files, compare light distributions and save your analysis locally.

Open Viewer

Light quality

LED Spectrum Mixer

Mix example LED source spectra and compare CCT, Duv, Ra, R9 and R1–R14.

Open Calculator
For AI agents: instructions and calculation APIs

Read the tool instructions in Markdown and the request/response schemas in OpenAPI. These public calculation APIs run the same models as the web and offline calculators. No account, API key or Turnstile is required.

DMX DIP Switch Calculator

POST /api/tools/v1/dmx
Content-Type: application/json

This model uses 9 binary address switches, with switch 1 the least significant bit. Start addresses are 1–511; a fixture may end at channel 512. Hardware ON direction, inverted logic and mode switches must be checked in the device manual. Universe numbers are preserved without changing between zero-based and one-based numbering.

address-to-switches · switches-to-address · plan-addresses · check-overlaps

LED Voltage Drop Calculator

POST /api/tools/v1/voltage-drop
Content-Type: application/json

One two-conductor copper DC feed. cableLengthM is the one-way length; the return conductor is included. Enter SI values: metres, watts per metre, volts DC and degrees Celsius. The calculation excludes strip PCB, connector and controller losses, ampacity, fuse selection and brightness.

voltage-drop

LED Resistor Calculator

POST /api/tools/v1/led-resistor
Content-Type: application/json

One resistor in one series LED branch. Enter forward voltage for the complete LED package and target current in milliamps. SMD 2835 describes the LED dimensions, not voltage/current; resistor footprints are separate. This is not a voltage-reduction tool for a finished strip.

led-resistor

Pixel LED Address Planner

POST /api/tools/v1/pixel-plan
Content-Type: application/json

Plan independently wired pixel LED runs. Enter independently addressable physical pixels, not LED packages. Each run instance uses one output. Grouping reduces control points and input channels; it does not reduce physical pixel load, power or wiring requirements.

pixel-plan

Lighting Electricity Cost Calculator

POST /api/tools/v1/lighting-cost
Content-Type: application/json

Estimate lighting electricity use at one flat tariff for a 365-day year. Enter metres, watts, watts per metre, operating hours per day and operating days per year. Each group uses exactly one power basis: strip output, fixture input including its driver, or measured wall-side input. This is an estimate for the entered lighting groups, not the complete electricity bill or a guarantee of measured consumption.

lighting-cost

DALI Bus Capacity Planner

POST /api/tools/v1/dali
Content-Type: application/json

Plan wired DALI-2 physical devices with separate control-gear and control-device address pools. Each physical device is indivisible; same-name areas remain together when keepAreas=true. Enter bus consumption in mA, not LED output/mains current. Every bus receives the same entered supply and controller-interface budget. This does not commission hardware or verify product compatibility.

dali

Constant-Current LED Driver Checker

POST /api/tools/v1/driver-match
Content-Type: application/json

One series string of identical modules at a declared target operating current. Voltages are V, currents mA, power W and tolerance percent. Use the complete module Vf range for the intended current, bin and temperature, and the driver CC region at that setting. Typical or reference-only datasheet values are not guaranteed limits. CC+CV is evaluated only in its CC region; CV-only is unsupported.

driver-match

Indoor Lighting Calculator

POST /api/tools/v1/indoor-lighting
Content-Type: application/json

Early sizing with the lumen method, using complete-luminaire output. The result is an average on the calculation plane, not a point-by-point photometric design. Natural light, uniformity, glare, fixture positions and compliance are excluded.

fixtures · lumens · check

Emergency Lighting Battery Calculator

POST /api/tools/v1/emergency-lighting-battery
Content-Type: application/json

Estimate a constant emergency load on one battery or bank. Results are conditional energy budgets, not a battery discharge curve, illuminance calculation, equipment recommendation or compliance approval. Obtain the operating assumptions from the user or equipment data; do not silently use the editable web examples.

estimate-runtime · size-battery

Illuminance & Uniformity Analyzer

POST /api/tools/v1/illuminance
Content-Type: application/json

Analyze recorded illuminance on one horizontal rectangular area, sampled at equal-area cell centres. This is measurement analysis, not a lighting simulation. Supply every physical input explicitly in metres and lux. It does not use a phone sensor, invent readings or assess compliance, calibration or measurement uncertainty.

illuminance

IES / LDT Photometric Viewer

POST /api/tools/v1/photometry
Content-Type: application/json

Read Type C IES with TILT=NONE or single-lamp-set EULUMDAT text. Return file facts, integrated flux and full-width beam metrics, plus every requested intensity query in candela. This does not verify laboratory measurements or replace a lighting design study.

Photometry JSON bodies are limited to 1024 KiB, independently of the browser file limit. The parsed table is limited to 250000 cells per file; HTTP results include only the explicitly queried directions and full-file metrics, not a silent partial export of the native table.

photometry

LED Spectrum Mixer

POST /api/tools/v1/spectrum-mixer
Content-Type: application/json

Mix the seven example source spectra exposed by this tool: warm white, cool white, red, green, blue, amber and violet. Weights are relative 0–100 inputs; omitted sources contribute zero. The CIE LED-B1/B5 arrays and Gaussian colour sources are educational examples, not LEDYI product measurements or calibrated dimmer settings.

spectrum-mixer

Request limits and errors

Send uncompressed application/json with strict types and no query parameters. Indoor lighting bodies are limited to 16 KiB; driver-match bodies to 16 KiB; battery bodies to 16 KiB; voltage bodies to 16 KiB; resistor bodies to 16 KiB; spectrum bodies to 16 KiB; DMX bodies to 1024 KiB and 1000 fixtures; pixel bodies to 64 KiB, 64 run rows, 128 outputs and 2000000 channels. DALI bodies are limited to 64 KiB, 24 rows and 512 devices. Illuminance bodies are limited to 16 KiB and 400 planned points. Photometry bodies are limited to 1024 KiB with up to 4 files and 16 by 721 query directions per file. Lighting-cost bodies are limited to 64 KiB with up to 20 groups in each scenario. Body reading expires after 5 seconds. Complete success JSON is bounded to 4 MiB. GET/HEAD return 405; OPTIONS returns 204. Source responses are no-store. Anonymous browser CORS permits POST/OPTIONS and Content-Type with credentials omitted.

Tool POST requests and ordinary page requests share 120 requests per 60 seconds per IP/Cloudflare location; mitigation lasts 60 seconds. Heavy tool use can temporarily block pages from the same source. This is not an independent or globally exact API quota. Inquiry/search use their existing separate rule. Tool POST requests do not inherit the company-page or verified-bot exemption.

Cloudflare can return 403/429/5xx before the application, sometimes as HTML without CORS or Retry-After. Check HTTP status and Content-Type before parsing JSON. A browser may see only a network error. Do not present an error or an older result as a successful new calculation.