Lighting Electricity Cost Calculator

Estimate running costs. Compare setups. See what a change could save.

Your running cost

USD

Electricity use and cost by period
Save

Electricity costs only. Excludes fixed charges, demand charges and maintenance. Flat-rate estimate; no automatic tariff lookup.

Good to know

Which power figure should I enter?

For LED strips, use watts per metre or foot from the strip’s specification. For fixtures, use the total input watts per fixture, including its driver. For a measured setup, use the wattmeter reading for the entire group at the mains input.

A power supply’s 150 W rating describes its output capacity. It does not mean your lights continuously consume 150 W. “60 W equivalent” describes light output, not actual LED power consumption.

Does 50% brightness mean half the cost?

Not necessarily. The relationship depends on the driver, dimming method and LED channels in use. Colour and colour temperature can also affect the power of RGB and tunable-white strips.

For an estimate at your usual brightness, choose Measured and enter the wall-side watts at that setting. Rated strip power gives a nominal full-power estimate.

What does driver efficiency change?

The driver draws more power from the mains than it supplies to the strip. A 72 W strip with a 90% efficient driver draws an estimated 80 W: 72 ÷ 0.90.

The 90% starting value is an example. Actual efficiency varies with the driver and load. Fixture input ratings and wall-side measurements already include driver losses, so the calculator does not add them again.

Which electricity price should I use?

Use your bill’s per-kWh electricity charge, including other charges proportional to kWh if applicable. Enter 0.20 for 20 cents. Do not divide the whole bill by kWh if it includes fixed or demand charges.

This tool uses one flat rate. For a time-of-use tariff, use a usage-weighted average for the hours your lighting runs. The currency selector changes the label, not the exchange rate.

How are monthly costs and standby calculated?

Operating hours are hours per day × days per year. Monthly average is the annual total divided by 12; daily average is divided by 365. These are annualised averages, not a forecast for a particular bill.

Standby power applies to 8,760 minus the operating hours. This assumes the group stays connected all year. Use 0 W if a mains switch disconnects the entire group whenever it is off.

What does the payback figure include?

Simple payback is the extra upfront cost divided by annual electricity savings. For an upgrade, include the replacement equipment and installation, less rebates. For two new proposals, enter the difference between their installed costs.

It excludes financing, tariff changes, maintenance and replacement. If the alternative does not lower electricity costs, there is no simple payback from electricity savings.

Share this calculation

This link includes your inputs, results and any saved comparison. Anyone with the link can read the group names and figures.

Remove this lighting group?

Reset to the example?

This replaces the current inputs and removes any added groups or comparison.

For AI agents: instructions and calculation APIs

Read the tool instructions in Markdown and the request/response schemas in OpenAPI. These public calculation APIs run the same models as the web and offline calculators. No account, API key or Turnstile is required.

Lighting Electricity Cost Calculator

POST /api/tools/v1/lighting-cost
Content-Type: application/json

Estimate lighting electricity use at one flat tariff for a 365-day year. Enter metres, watts, watts per metre, operating hours per day and operating days per year. Each group uses exactly one power basis: strip output, fixture input including its driver, or measured wall-side input. This is an estimate for the entered lighting groups, not the complete electricity bill or a guarantee of measured consumption.

lighting-cost

Lighting energy, running costs and comparison

Provide currency, electricityRatePerKwh and baseline.groups. Each group needs name, power, hoursPerDay, daysPerYear and standbyInputPowerW. comparison is optional. Within comparison, additionalInvestment is the extra equipment and installation cost less rebates; null or omission means unknown, while 0 explicitly means no extra cost. This example compares measured 80 W and 40 W at 8 h/day, 365 days/year and 0.20 USD/kWh: annual costs 46.72 and 23.36, annual savings 23.36, payback investment-unknown.

{
  "currency": "USD",
  "electricityRatePerKwh": 0.2,
  "baseline": {
    "groups": [
      {
        "name": "Current lighting",
        "power": {
          "kind": "measured",
          "inputPowerW": 80
        },
        "hoursPerDay": 8,
        "daysPerYear": 365,
        "standbyInputPowerW": 0
      }
    ]
  },
  "comparison": {
    "groups": [
      {
        "name": "Alternative lighting",
        "power": {
          "kind": "measured",
          "inputPowerW": 40
        },
        "hoursPerDay": 8,
        "daysPerYear": 365,
        "standbyInputPowerW": 0
      }
    ],
    "additionalInvestment": null
  }
}

Open links.share to restore the normalized SI inputs in the calculator; API shares display metres. New shares use project version 2 and preserve unknown investment as null; old version 1 shares preserve their explicit zero. A valid project exceeding the existing URL bound has links.share=null with LIGHTING_SHARE_URL_TOO_LONG; its calculation is still complete. Compare equivalent lighting requirements. Dimming/colour need representative measured wall watts; no universal brightness-to-power ratio or currency conversion is assumed. Copy, CSV, printing and offline HTML use the same model. The offline download endpoint provides the HTML calculator template; it does not calculate a request.

Request limits and errors

Send uncompressed application/json with strict types and no query parameters. Indoor lighting bodies are limited to 16 KiB; driver-match bodies to 16 KiB; battery bodies to 16 KiB; voltage bodies to 16 KiB; resistor bodies to 16 KiB; spectrum bodies to 16 KiB; DMX bodies to 1024 KiB and 1000 fixtures; pixel bodies to 64 KiB, 64 run rows, 128 outputs and 2000000 channels. DALI bodies are limited to 64 KiB, 24 rows and 512 devices. Illuminance bodies are limited to 16 KiB and 400 planned points. Photometry bodies are limited to 1024 KiB with up to 4 files and 16 by 721 query directions per file. Lighting-cost bodies are limited to 64 KiB with up to 20 groups in each scenario. Body reading expires after 5 seconds. Complete success JSON is bounded to 4 MiB. GET/HEAD return 405; OPTIONS returns 204. Source responses are no-store. Anonymous browser CORS permits POST/OPTIONS and Content-Type with credentials omitted.

Tool POST requests and ordinary page requests share 120 requests per 60 seconds per IP/Cloudflare location; mitigation lasts 60 seconds. Heavy tool use can temporarily block pages from the same source. This is not an independent or globally exact API quota. Inquiry/search use their existing separate rule. Tool POST requests do not inherit the company-page or verified-bot exemption.

Cloudflare can return 403/429/5xx before the application, sometimes as HTML without CORS or Retry-After. Check HTTP status and Content-Type before parsing JSON. A browser may see only a network error. Do not present an error or an older result as a successful new calculation.

Local example and calculator inputs

Run the displayed request locally, or replace it with a snapshot of your calculator inputs. This does not send an HTTP request.