# LED Voltage Drop Calculator

Compare copper wire sizes for an LED strip, calculate voltage drop, and share or save your setup and results.

## For AI agents: instructions and calculation APIs

Read the tool instructions in Markdown and the request/response schemas in OpenAPI. These public calculation APIs run the same models as the web and offline calculators. No account, API key or Turnstile is required.

- [LED Voltage Drop Calculator — Full tool instructions (Markdown)](https://ledyi.com/tools/voltage-drop-calculator.md)
- [OpenAPI contract](https://ledyi.com/openapi.json)
- [Agent site index](https://ledyi.com/llms.txt)

Your agent needs an HTTP tool permitted to send POST requests. Reading this page or importing OpenAPI does not automatically grant execution access.

### LED Voltage Drop Calculator

```
POST /api/tools/v1/voltage-drop
Content-Type: application/json
```

One two-conductor copper DC feed. cableLengthM is the one-way length; the return conductor is included. Enter SI values: metres, watts per metre, volts DC and degrees Celsius. The calculation excludes strip PCB, connector and controller losses, ampacity, fuse selection and brightness.

### Voltage drop and wire comparison

One two-conductor copper DC feed. cableLengthM is the one-way length; the return conductor is included. Enter SI values: metres, watts per metre, volts DC and degrees Celsius. The calculation excludes strip PCB, connector and controller losses, ampacity, fuse selection and brightness.

| Field | Type and constraints | Meaning |
| --- | --- | --- |
| supplyVoltageV (Required) | {"type":"number","enum":[5,12,24,48]} | Rated supply voltage (V DC). |
| stripLengthM (Required) | {"type":"number","exclusiveMinimum":0,"maximum":1000} | Strip length carried by this feed (m). |
| powerPerMeterW (Required) | {"type":"number","exclusiveMinimum":0,"maximum":1000} | Rated strip power (W/m), not PSU rating. |
| cableLengthM (Required) | {"type":"number","exclusiveMinimum":0,"maximum":1000} | One-way cable route (m); both conductors are counted. |
| temperatureC (Required) | {"type":"number","minimum":-20,"maximum":90} | Copper conductor temperature during use (°C). |
| maxDropPercent (Required) | {"type":"number","minimum":0.5,"maximum":10} | Percentage: 3 means 3%, not 0.03. |
| wireCatalog (Required) | {"type":"string","enum":["metric","awg"]} | Copper size catalog; nominal area is not outside cable diameter. |
| selectedWireId (Optional) | {"anyOf":[{"anyOf":[{"type":"string","enum":["metric:0.14","metric:0.25","metric:0.34","metric:0.5","metric:0.75","metric:1","metric:1.5","metric:2.5","metric:4","metric:6","metric:10","metric:16","metric:25","metric:35","awg:28","awg:26","awg:24","awg:22","awg:20","awg:18","awg:16","awg:14","awg:12","awg:10","awg:8","awg:6","awg:4","awg:2","awg:1/0"]},{"type":"null"}]}],"default":null} | Must belong to wireCatalog; null selects the minimum passing size. |

```
{
  "supplyVoltageV": 24,
  "stripLengthM": 5,
  "powerPerMeterW": 14.4,
  "cableLengthM": 5,
  "temperatureC": 40,
  "maxDropPercent": 3,
  "wireCatalog": "metric",
  "selectedWireId": null
}
```

### Reading the result

Load P = stripLengthM × powerPerMeterW; nominal current I = P / supplyVoltageV; copper resistivity ρ(T) = 0.01724 × (1 + 0.00393 × (T − 20)); cable resistance R = 2 × ρ(T) × cableLengthM / areaMm2. Voltage drop = I × R. Minimum PSU output = P / 0.8; this is rating headroom, not efficiency or AC input power.

For feet: metres = feet × 0.3048; watts per metre = watts per foot / 0.3048. selectedWireId must belong to wireCatalog. The catalog IDs and allowed values are listed below.

A successful response contains all sizes in the chosen catalog, their voltageDropV, voltageDropPercent, voltageAtStripInputV, maxCableLengthM and passesDropTarget. recommendedWireId is the smallest passing area. No matching wire is a valid result: status=no-catalog-match and recommendedWireId=null. Explicit selection is preserved even when it fails. A drop reaching supply voltage gives voltageAtStripInputV=null and estimateStatus=drop-reaches-supply. Decisions use unrounded model values.

Missing physical inputs, numeric strings, unknown fields and a selected wire from the wrong catalog return 422. Unrepresentable numerical combinations also return 422; the service never replaces them with the browser example.

Open links.share to restore these SI inputs and the selected wire in the calculator. API shares display metres. The web calculator can copy results, export all wire rows as CSV, print or save PDF, and download a working offline HTML copy. The offline download endpoint is not a calculation API.

### Request limits and errors

Every success carries apiVersion, a server-generated requestId, operation, normalized inputs, result, warnings and links (tool, markdown, openapi, share). requestId also appears in X-Request-Id. The domain result is deterministic; the request ID changes. Preserve warnings and special statuses when explaining results.

Send uncompressed application/json with strict types and no query parameters. Indoor lighting bodies are limited to 16 KiB; driver-match bodies to 16 KiB; battery bodies to 16 KiB; voltage bodies to 16 KiB; resistor bodies to 16 KiB; spectrum bodies to 16 KiB; DMX bodies to 1024 KiB and 1000 fixtures; pixel bodies to 64 KiB, 64 run rows, 128 outputs and 2000000 channels. DALI bodies are limited to 64 KiB, 24 rows and 512 devices. Illuminance bodies are limited to 16 KiB and 400 planned points. Photometry bodies are limited to 1024 KiB with up to 4 files and 16 by 721 query directions per file. Lighting-cost bodies are limited to 64 KiB with up to 20 groups in each scenario. Body reading expires after 5 seconds. Complete success JSON is bounded to 4 MiB. GET/HEAD return 405; OPTIONS returns 204. Source responses are no-store. Anonymous browser CORS permits POST/OPTIONS and Content-Type with credentials omitted.

Tool POST requests and ordinary page requests share 120 requests per 60 seconds per IP/Cloudflare location; mitigation lasts 60 seconds. Heavy tool use can temporarily block pages from the same source. This is not an independent or globally exact API quota. Inquiry/search use their existing separate rule. Tool POST requests do not inherit the company-page or verified-bot exemption.

Source errors use application/problem+json with status, stable code, requestId and at most one invalidParams JSON pointer. 400: malformed JSON/query; 405: method; 408: body timeout; 413: body limit; 415: media/encoding; 422: parameter/domain error; 500/503: service failure. Fix invalid inputs rather than retrying or changing engineering facts. For 429 or transient failures, use at most two retries with backoff and jitter, honoring Retry-After when present.

Cloudflare can return 403/429/5xx before the application, sometimes as HTML without CORS or Retry-After. Check HTTP status and Content-Type before parsing JSON. A browser may see only a network error. Do not present an error or an older result as a successful new calculation.

Calculations do not create inquiries, send emails, call a language model or store project results. Operational logs exclude fixture labels, groups and request bodies. Existing network/access logs still apply. Submit a quotation request only when the user asks, using the separate inquiry contract and buyer confirmation flow.

### Warning codes

| Field | Meaning |
| --- | --- |
| VOLTAGE_NO_CATALOG_MATCH | The selected catalog has no wire meeting the drop target. |
| VOLTAGE_SELECTED_WIRE_EXCEEDS_TARGET | The explicitly selected wire exceeds the target. |
| VOLTAGE_SELECTED_ESTIMATE_OUTSIDE_MODEL | The explicitly selected wire reaches/exceeds supply voltage; its output voltage estimate is null. |

### Error codes

```
TOOLS_INVALID_JSON
TOOLS_QUERY_UNSUPPORTED
TOOLS_METHOD_NOT_ALLOWED
TOOLS_BODY_TIMEOUT
TOOLS_BODY_TOO_LARGE
TOOLS_MEDIA_TYPE_UNSUPPORTED
TOOLS_CONTENT_ENCODING_UNSUPPORTED
TOOLS_INPUT_INVALID
TOOLS_NUMERIC_DOMAIN_UNSUPPORTED
TOOLS_INTERNAL_ERROR
TOOLS_SERVICE_UNAVAILABLE
DMX_INPUT_INVALID
DMX_ADDRESS_NOT_ENCODABLE
DMX_CHANNEL_RANGE_EXCEEDED
DMX_SPACING_OVERLAP
DMX_UNIVERSE_RANGE_EXCEEDED
PHOTOMETRY_FILE_INVALID
PHOTOMETRY_FILE_UNSUPPORTED
PHOTOMETRY_LIMIT_EXCEEDED
```

## Which wire size should I choose?

Start with the size marked Minimum : it is the smallest listed copper conductor that meets your voltage-drop target. A larger conductor reduces the drop further. Then check the cable's current rating, terminal capacity and installation requirements. Meeting the voltage-drop target alone does not confirm a cable is suitable.

## Is cable length one-way or round-trip?

Enter the distance from the power supply to the LED strip, measured along the cable route. For a 5 m cable, enter 5 m. The calculator includes the outgoing and return conductors automatically. Strip length is a separate input. It sets the load; it is not added to the supply cable length.

## Will this tell me if the end of my strip is dim?

The result is the voltage at the start of the strip . A long LED strip can lose additional voltage through its own copper PCB. Follow the strip's maximum run length and feed instructions. Separate feeds or power injection may be needed; calculate each supply cable using the load it carries.

## What if the voltage drop is too high?

Try a larger copper conductor, shorten the cable route or split the load into separate feeds. Each feed needs its own calculation. A higher system voltage reduces cable drop for the same rated load, but only change voltage if the strip, power supply and controller all support it. Do not raise the supply above the strip's rated voltage.

## How is the power supply rating calculated?

Strip length × rated power gives the LED load. Divide that load by 0.8 to keep it at or below 80% of the power supply's rating. For example, a 72 W strip needs at least 90 W at the strip's specified voltage. Choose a suitable available rating and account for other loads, power-supply derating and the manufacturer's requirements.

## Calculation method and assumptions

This is a nominal-current estimate for one two-conductor copper DC feed. I = P ÷ V R = 2 × ρ(T) × L ÷ A Voltage drop = I × R Copper resistivity at 20°C: 0.01724 Ω·mm²/m. Temperature coefficient: 0.00393/°C. AWG areas use the standard geometric formula; mm² and AWG are separate size catalogs. Actual current depends on the strip and its input voltage. This tool does not calculate AC wiring, copper-clad aluminum, multi-channel cable losses, ampacity, fuse size or brightness.

## Can I type a length instead of dragging?

Yes. Use the number field for an exact length. The slider and field control the same value, and the comparison updates immediately. Typing a longer run expands the slider's range. Click or tap a wire to keep it selected while changing the lengths. Use Use minimum to switch back to the smallest size that meets your target.

## Do these sizes mean the cable's diameter?

mm² is the copper conductor's cross-sectional area , not the cable's outside diameter. AWG is a separate gauge system: a lower AWG number means a larger conductor. The lists use available nominal conductor sizes. A nearby AWG and mm² size are not exact equivalents. Smaller sizes may suit light loads and short connections; always check the cable's current rating and installation suitability.